Fluke I5SPQ3 AC Current Clamp, 600V AC Voltage, 5A AC Current (Pack of 3)
|
상품가격 상세보기
이벤트보기
|
- 상품상세정보
상품특징
Make sure this fits by entering your model number.Low level current clamp measures up to 5A ACCompact shape makes transporting and storing convenientTake accurate readings without breaking the circuitCAT III 600 V (For insulated conductors only)1 year warranty
상품설명
Size:Pack of 3 A pack of 3 pieces of the i5s current clamps, specially configured to provide low current accuracy while taking measurements on secondary current transformers. This cost-saving 3-pack is perfect for use with 3-phase tools such as the Fluke 434 or Fluke 435. Compact shape makes transporting and storing convenient. Take accurate readings without breaking the circuit. CAT III 600 V (For insulated conductors only). Nominal current range: 5A. Continuous current range: 10mA to 6A. Maximum non-destructive current: 70A. Lowest measurable current: 10mA. Basic accuracy: 10mA to 1A: 1 percent + 5 mA, 1A to 5A: 1 percent. Useable frequency: 40 Hz to 5 kHz. Output levels: 400 mV/A. Input load impedance: greater than 1 mega ohm in parallel with up to 47 pF. Crest factor: less than or equal to 3, add 0.7 percent to accuracy. Safety: CAT III 600V per IEC/EN61010-1, Pollution Degree 2. Maximum voltage: 600V AC. Maximum conductor diameter: 15mm. Output cable length: 2.5m. With BNC adapter. Measures 116mm length by 43mm width by 23mm height.
Make sure this fits by entering your model number.Low level current clamp measures up to 5A ACCompact shape makes transporting and storing convenientTake accurate readings without breaking the circuitCAT III 600 V (For insulated conductors only)1 year warranty
상품설명
Size:Pack of 3 A pack of 3 pieces of the i5s current clamps, specially configured to provide low current accuracy while taking measurements on secondary current transformers. This cost-saving 3-pack is perfect for use with 3-phase tools such as the Fluke 434 or Fluke 435. Compact shape makes transporting and storing convenient. Take accurate readings without breaking the circuit. CAT III 600 V (For insulated conductors only). Nominal current range: 5A. Continuous current range: 10mA to 6A. Maximum non-destructive current: 70A. Lowest measurable current: 10mA. Basic accuracy: 10mA to 1A: 1 percent + 5 mA, 1A to 5A: 1 percent. Useable frequency: 40 Hz to 5 kHz. Output levels: 400 mV/A. Input load impedance: greater than 1 mega ohm in parallel with up to 47 pF. Crest factor: less than or equal to 3, add 0.7 percent to accuracy. Safety: CAT III 600V per IEC/EN61010-1, Pollution Degree 2. Maximum voltage: 600V AC. Maximum conductor diameter: 15mm. Output cable length: 2.5m. With BNC adapter. Measures 116mm length by 43mm width by 23mm height.
2021-07-21 09:40:51