Protektive Pak 37750 Stacking Board Handler Tek Tray, 18" Length x 11-3/8" Width x 1-3/4" Depth (Case of 6)
|
상품가격 상세보기
이벤트보기
|
- 상품상세정보
상품설명
High voltage discharge resistance failure rate 0/5 (no oxide damage in five consecutive tests). Static shielding 99.9 percent attenuation at 10kV; 99.6 percent attenuation at 30kV. Charged device model (CDM) safety RTG >107 ohms at 86 percent R.H. or less. Current carrying hazard 103 mA at 110V; 103 mA at 220V. Corrosivity contains 1-3 ppm reducible sulfur. No antistat transfer. surface resistivity, Low R.H. cut-off 4 percent R.H. surface resistivity 107 - 108 ohms/sq. after 11 days at 68 degree F and 12 percent R.H. for surface. 103 - 104 ohms/sq. for buried shielding layer. Electrostatic decay 0.01 seconds at 72 degree F and 11.8 percent R.H. Water and isopropyl alcohol extraction surface resistivity 108 - 109 ohms/square at 74 degree F. Tests for antistat permanence and 36 percent R.H. Sloughing test negligible surface damage at 10 cycles and <5 percent of surface damage at 200 cycles in Taber Abrasion Test. No conductive particles abrased from surface. Complete recyclability of package. Biodegradation in or on moist soil. Volume Conductivity from wall to wall as well as across surface to assure permanence of the antistatic property. Shelf life indefinite.
High voltage discharge resistance failure rate 0/5 (no oxide damage in five consecutive tests). Static shielding 99.9 percent attenuation at 10kV; 99.6 percent attenuation at 30kV. Charged device model (CDM) safety RTG >107 ohms at 86 percent R.H. or less. Current carrying hazard 103 mA at 110V; 103 mA at 220V. Corrosivity contains 1-3 ppm reducible sulfur. No antistat transfer. surface resistivity, Low R.H. cut-off 4 percent R.H. surface resistivity 107 - 108 ohms/sq. after 11 days at 68 degree F and 12 percent R.H. for surface. 103 - 104 ohms/sq. for buried shielding layer. Electrostatic decay 0.01 seconds at 72 degree F and 11.8 percent R.H. Water and isopropyl alcohol extraction surface resistivity 108 - 109 ohms/square at 74 degree F. Tests for antistat permanence and 36 percent R.H. Sloughing test negligible surface damage at 10 cycles and <5 percent of surface damage at 200 cycles in Taber Abrasion Test. No conductive particles abrased from surface. Complete recyclability of package. Biodegradation in or on moist soil. Volume Conductivity from wall to wall as well as across surface to assure permanence of the antistatic property. Shelf life indefinite.
2019-04-29 21:24:11