Siemens ECSBPK02 Generator Standby Power Mechanical Interlock
|
상품가격 상세보기
이벤트보기
|
- 상품상세정보
상품특징
Make sure this fits by entering your model number.UL ListedFor use on Siemens or Murray panelsMain breaker is double pole QP breaker 15-125 AmpStandby power breaker is a QP or MP typeNo modification of panel required; Breakers not included
상품설명
Amazon.com Siemens standby power mechanical interlock kits provide a means to ensure that the main breaker powered by utility power within a panel is forced to the OFF position when standby power is in use. It also ensures that the standby source is forced to the OFF position when the utility power is in use. This model (ECSBPK02) is designed for use on load centers or meter combinations that will accept 2- or 4-pole next to a 2-pole circuit breaker side by side. It's compatible with QP, QPH, and HQPH utility main breaker and standby main breaker types. The most common application for an interlock kits is when a portable generator is used to provide back up power to a building. If the utility main breaker in a panel is left in the -"ON"-position while a generator is powering the panel, dangerous back feeding of the utility power lines can occur. The ECSBPK02 interlock kit ( view larger ). Use on Siemens or Murray panels ( view larger ). ECSBPK02 Generator Standby Power Mechanical Interlock At a Glance UL listed for use in most Siemens load centers and meter combinations Remains attached to the main breakers when load center cover Corrosion resistant finish For use on Siemens or Murray panels Easy assembly requiring no modifications to the load center or meter combination Suitable for use with optional standby systems in accordance with article 702 of the National Electric Code From the Manufacturer Siemens standby power mechanical interlock kits provide a means to ensure that the Main breaker powered by utility power within a panel is forced to the OFF position when standby power is in use. It also ensures that the standby source is forced to the OFF position when the utility power is in use. The most common application for these kits is when a portable generator is used to provide back up power to a building. If the utility Main breaker in a panel is left in the -"ON"-position while a generator is powering the panel, dangerous back feeding of the utility power lines can occur. The ECSBPK02 will work on any Siemens or Murray Load Center in which the Main breaker and standby power breaker are backfed, two pole, QP or MP type breakers.
Make sure this fits by entering your model number.UL ListedFor use on Siemens or Murray panelsMain breaker is double pole QP breaker 15-125 AmpStandby power breaker is a QP or MP typeNo modification of panel required; Breakers not included
상품설명
Amazon.com Siemens standby power mechanical interlock kits provide a means to ensure that the main breaker powered by utility power within a panel is forced to the OFF position when standby power is in use. It also ensures that the standby source is forced to the OFF position when the utility power is in use. This model (ECSBPK02) is designed for use on load centers or meter combinations that will accept 2- or 4-pole next to a 2-pole circuit breaker side by side. It's compatible with QP, QPH, and HQPH utility main breaker and standby main breaker types. The most common application for an interlock kits is when a portable generator is used to provide back up power to a building. If the utility main breaker in a panel is left in the -"ON"-position while a generator is powering the panel, dangerous back feeding of the utility power lines can occur. The ECSBPK02 interlock kit ( view larger ). Use on Siemens or Murray panels ( view larger ). ECSBPK02 Generator Standby Power Mechanical Interlock At a Glance UL listed for use in most Siemens load centers and meter combinations Remains attached to the main breakers when load center cover Corrosion resistant finish For use on Siemens or Murray panels Easy assembly requiring no modifications to the load center or meter combination Suitable for use with optional standby systems in accordance with article 702 of the National Electric Code From the Manufacturer Siemens standby power mechanical interlock kits provide a means to ensure that the Main breaker powered by utility power within a panel is forced to the OFF position when standby power is in use. It also ensures that the standby source is forced to the OFF position when the utility power is in use. The most common application for these kits is when a portable generator is used to provide back up power to a building. If the utility Main breaker in a panel is left in the -"ON"-position while a generator is powering the panel, dangerous back feeding of the utility power lines can occur. The ECSBPK02 will work on any Siemens or Murray Load Center in which the Main breaker and standby power breaker are backfed, two pole, QP or MP type breakers.
2021-10-20 23:59:31