CR Magnetics CR4850-50 3-Element 3-Wire Average RMS AC Voltage Transducer, 20 Hz - 5 KHz, >=2K Output Load, 24 VDC +/-10%, 0-50 VAC Input Range, 0 - 5 VDC Output Range
|
상품가격 상세보기
이벤트보기
|
- 상품상세정보
상품특징
Make sure this fits by entering your model number.Average RMS measurement for sinusoidal alternating voltage waveforms0.5% FS accuracyResponse time of 250 ms (10-90% step change)Three-wire input for measurement of three-phase voltageUL Recognized and CE certified for quality assurance
상품설명
Size:0-50 VAC Input Range This CR Magnetics CR4850 series voltage transducer combines a potential transformer and signal conditioner, and is suitable for use in industrial automation systems. The transducer provides average root-mean-square (RMS) measurement for sinusoidal alternating voltage waveforms, with an accuracy of 0.5% full scale (FS) and a response time of 250 ms (10-90% step change). A three-wire input allows for measurement of three-phase voltage. This voltage transducer is Underwriters Laboratories (UR) Recognized and Conformité Européenne (CE) certified for quality assurance. It is suitable for monitoring linear, constant-speed loads that produce sinusoidal waveforms.SpecificationsSignal Output0-5 VDCFrequency Range20-5,000 HzInsulation Voltage2,500 VDCOutput Loading2 K ohm minimumOperating Temperature0 C to 60 C CR Magnetics manufactures electrical sensors, indicators, and displays. The company, founded in 2004, is headquartered in Saint Louis, MO.
Make sure this fits by entering your model number.Average RMS measurement for sinusoidal alternating voltage waveforms0.5% FS accuracyResponse time of 250 ms (10-90% step change)Three-wire input for measurement of three-phase voltageUL Recognized and CE certified for quality assurance
상품설명
Size:0-50 VAC Input Range This CR Magnetics CR4850 series voltage transducer combines a potential transformer and signal conditioner, and is suitable for use in industrial automation systems. The transducer provides average root-mean-square (RMS) measurement for sinusoidal alternating voltage waveforms, with an accuracy of 0.5% full scale (FS) and a response time of 250 ms (10-90% step change). A three-wire input allows for measurement of three-phase voltage. This voltage transducer is Underwriters Laboratories (UR) Recognized and Conformité Européenne (CE) certified for quality assurance. It is suitable for monitoring linear, constant-speed loads that produce sinusoidal waveforms.SpecificationsSignal Output0-5 VDCFrequency Range20-5,000 HzInsulation Voltage2,500 VDCOutput Loading2 K ohm minimumOperating Temperature0 C to 60 C CR Magnetics manufactures electrical sensors, indicators, and displays. The company, founded in 2004, is headquartered in Saint Louis, MO.