CR Magnetics CR4550-50 True RMS AC Voltage Transducer with 3 Phase and 3 Wire, 20 Hz - 5 KHz, >= 2K Output Load, 24 VDC +/-10%, 0-50 VAC Input Range, 0 - 5 VDC Output Range
|
상품가격 상세보기
이벤트보기
|
- 상품상세정보
상품특징
True RMS measurement for distorted alternating voltage waveforms0.5% FS accuracyResponse time of 250 ms (10-90% step change)Three-wire input for measurement of three-phase loadsUL Recognized and CE certified for quality assurance
상품설명
This CR Magnetics CR4550 series voltage transducer combines a potential transformer and signal conditioner, and is suitable for use in industrial automation systems. The transducer provides true root-mean-square (RMS) measurement for distorted voltage waveforms, with an accuracy of 0.5% full scale (FS) and a response time of 250 ms (10-90% step change). A three-wire input allows for measurement of three-phase loads. This voltage transducer is Underwriters Laboratories (UR) Recognized and Conformité Européenne (CE) certified for quality assurance. It is suitable for monitoring variable-frequency drive (VFD) and silicone control rectifier (SCR) loads and other "noisy" loads that produce distorted waveforms. Specifications Signal Output0-5 VDCFrequency Range20-5,000 HzInsulation Voltage2,500 VDCOutput Loading2 K ohm minimumOperating Temperature0 C to 50 C CR Magnetics manufactures electrical sensors, indicators, and displays. The company, founded in 2004, is headquartered in Saint Louis, MO.
True RMS measurement for distorted alternating voltage waveforms0.5% FS accuracyResponse time of 250 ms (10-90% step change)Three-wire input for measurement of three-phase loadsUL Recognized and CE certified for quality assurance
상품설명
This CR Magnetics CR4550 series voltage transducer combines a potential transformer and signal conditioner, and is suitable for use in industrial automation systems. The transducer provides true root-mean-square (RMS) measurement for distorted voltage waveforms, with an accuracy of 0.5% full scale (FS) and a response time of 250 ms (10-90% step change). A three-wire input allows for measurement of three-phase loads. This voltage transducer is Underwriters Laboratories (UR) Recognized and Conformité Européenne (CE) certified for quality assurance. It is suitable for monitoring variable-frequency drive (VFD) and silicone control rectifier (SCR) loads and other "noisy" loads that produce distorted waveforms. Specifications Signal Output0-5 VDCFrequency Range20-5,000 HzInsulation Voltage2,500 VDCOutput Loading2 K ohm minimumOperating Temperature0 C to 50 C CR Magnetics manufactures electrical sensors, indicators, and displays. The company, founded in 2004, is headquartered in Saint Louis, MO.
2019-03-20 13:55:37