CR Magnetics CR4511-50 True RMS AC Voltage Transducer with Single Element, 20 Hz - 5 KHz, >= 2K Output Load, 24 VDC +/-10%, 0-50 VAC Input Range, 0 - 10 VDC Output Range
|
상품가격 상세보기
이벤트보기
|
- 상품상세정보
상품특징
True RMS measurement for distorted alternating current waveforms0.5% FS accuracyResponse time of 250 ms (10-90% step change)User-selectable input voltage rangesUL Recognized and CE certified for quality assurance
상품설명
This CR Magnetics CR4511 series current transducer combines a solid-core current transformer and signal conditioner, and is suitable for use in industrial automation systems. The transducer provides true root-mean-square (RMS) measurement for distorted voltage waveforms, with an accuracy of 0.5% full scale (FS) and a response time of 250 ms (10-90% step change). Mounting options include DIN rail or panel. This voltage transducer is Underwriters Laboratories (UR) Recognized and Conformité Européenne (CE) certified for quality assurance. It is suitable for monitoring variable-frequency drive (VFD) and silicone control rectifier (SCR) loads and other "noisy" loads that produce distorted waveforms. Specifications Signal Output0-10 VDCFrequency Range20-5,000 HzInsulation Voltage2,500 VDCOutput Loading2 K ohm minimumOperating Temperature0 C to 50 C CR Magnetics manufactures electrical sensors, indicators, and displays. The company, founded in 2004, is headquartered in Saint Louis, MO.
True RMS measurement for distorted alternating current waveforms0.5% FS accuracyResponse time of 250 ms (10-90% step change)User-selectable input voltage rangesUL Recognized and CE certified for quality assurance
상품설명
This CR Magnetics CR4511 series current transducer combines a solid-core current transformer and signal conditioner, and is suitable for use in industrial automation systems. The transducer provides true root-mean-square (RMS) measurement for distorted voltage waveforms, with an accuracy of 0.5% full scale (FS) and a response time of 250 ms (10-90% step change). Mounting options include DIN rail or panel. This voltage transducer is Underwriters Laboratories (UR) Recognized and Conformité Européenne (CE) certified for quality assurance. It is suitable for monitoring variable-frequency drive (VFD) and silicone control rectifier (SCR) loads and other "noisy" loads that produce distorted waveforms. Specifications Signal Output0-10 VDCFrequency Range20-5,000 HzInsulation Voltage2,500 VDCOutput Loading2 K ohm minimumOperating Temperature0 C to 50 C CR Magnetics manufactures electrical sensors, indicators, and displays. The company, founded in 2004, is headquartered in Saint Louis, MO.
2019-04-19 14:10:18