BW Technologies XT-00HM-Y-NA GasAlertMax XT II 2-Gas Detector with Pump, H2S and CO, Yellow
ASIN번호 B00ANVEC9Q
상품상태 New   
상품구분 Tools & Home Improvement / Safety & Security
브랜드 BW Technologies
판매자 ONLINE DEALZ
판매자위치 미확인
현지 판매 가격
$966.55
상품가격 상세보기
관련상품



상품설명
BW Technologies 2-gas detector. Package contents are detector complete with specified sensors, stainless steel alligator clip and concussion-proof housing, Rechargeable lithium polymer battery, Charging adaptor, 3-feet/1-meter calibration hose with quick connect, 10-feet/3-meter sampling hose with particulate filter and quick connect, Reversible screwdriver, Kit of five spare pump filters, Manual, Multi-language CD manual. GasAlertMax XT II is the smart, simple, economical way to compliance. Simple operation, with SmartSample pump. GasAlertMax XT II reliably monitors up to four hazards and combines straightforward one-button operation with our robust, motorized pump for intelligent, remote sampling, ideal for confined spaces. The GasAlertMax XT II is fully compatible with MicroDock II automated test and calibration system. Continuous LCD shows real-time gas concentrations. Compact and lightweight design makes it comfortable to wear. Water-resistant. Simple automatic calibration procedure; compatible with BW MicroDock II automatic test and calibration station. Full function self-test of sensor, battery status, circuit integrity and audible/visual alarms on start up. Bright wide-angled visual alarm bars. Built-in concussion-proof boot. Humidity: 10 - 100 percent RH (non-condensing). Alarms: Visual, vibrating, audible (95dB); Low, High, STEL, TWA, OL (over limit), Low Battery, Pump. Tests: Audible/visual alarms on activation, sensors, battery, pump and circuitry (continuous). Typical battery life: 13 hours at 32 degree F/0 degree C, 8 hours at -4 degree F/-20 degree C, recharges in 6 hours. Pump draw: Sample from up to 75-feet/23-meters. Certifications and approvals: Class I, Div. 1, Gr. A, B, C, D; IECEx: Ga Ex ia IIC T4; ATEX: CE II 1 G Ga Ex ia IIC T4; Br Ex ia IIC T4. Measuring range for H2S is 0-200 ppm and for CO is 0-1000 ppm. Resolution is 1 ppm for H2S and CO.








상품설명
BW Technologies 2-gas detector. Package contents are detector complete with specified sensors, stainless steel alligator clip and concussion-proof housing, Rechargeable lithium polymer battery, Charging adaptor, 3-feet/1-meter calibration hose with quick connect, 10-feet/3-meter sampling hose with particulate filter and quick connect, Reversible screwdriver, Kit of five spare pump filters, Manual, Multi-language CD manual. GasAlertMax XT II is the smart, simple, economical way to compliance. Simple operation, with SmartSample pump. GasAlertMax XT II reliably monitors up to four hazards and combines straightforward one-button operation with our robust, motorized pump for intelligent, remote sampling, ideal for confined spaces. The GasAlertMax XT II is fully compatible with MicroDock II automated test and calibration system. Continuous LCD shows real-time gas concentrations. Compact and lightweight design makes it comfortable to wear. Water-resistant. Simple automatic calibration procedure; compatible with BW MicroDock II automatic test and calibration station. Full function self-test of sensor, battery status, circuit integrity and audible/visual alarms on start up. Bright wide-angled visual alarm bars. Built-in concussion-proof boot. Humidity: 10 - 100 percent RH (non-condensing). Alarms: Visual, vibrating, audible (95dB); Low, High, STEL, TWA, OL (over limit), Low Battery, Pump. Tests: Audible/visual alarms on activation, sensors, battery, pump and circuitry (continuous). Typical battery life: 13 hours at 32 degree F/0 degree C, 8 hours at -4 degree F/-20 degree C, recharges in 6 hours. Pump draw: Sample from up to 75-feet/23-meters. Certifications and approvals: Class I, Div. 1, Gr. A, B, C, D; IECEx: Ga Ex ia IIC T4; ATEX: CE II 1 G Ga Ex ia IIC T4; Br Ex ia IIC T4. Measuring range for H2S is 0-200 ppm and for CO is 0-1000 ppm. Resolution is 1 ppm for H2S and CO.




2019-05-01 15:58:59