Loulensy AC Voltage Transducer Voltage Sensor Transmitter Transformer Input 0-500V AC Output 0-5V DC
|
상품가격 상세보기
이벤트보기
|
- 상품상세정보
상품특징
Input:0-500V ACPower Consumption: less than 0.3 VAWorking Stability: annual change < 0.2%Impulse Voltage:5KV(peak value),1.2/50uSLoad Capacity: 2 times current continuousStorage Environment:-40 to +115 degress Centigrade,20%-95% without condensationIsolation Withstanding Voltage:AC 2.0KV/min*1mA between input/output/powerOutput:0-5V DCPower Supply(defaulted):24V DC +/-15% (If 15V or 12V needed,please leave a message)Dimension:99*24*65mm(L*W*H)Accuracy:0.5% F.SFeature:Voltage Terminal Insert,standard din rail(35mm)mounting or pannel mountingWorking Environment:-25 to 80 degrees Centigrade,20%-90% without condensationIsolation Resistance:20M Ohm(DC500V) or aboveCapacity Max:0-500V AC (Customerized,contact operator if you need other input ranges,e.g.0-75mV or 0-300V)
상품설명
This voltage transducer combines a potential transformer and signal conditioner, and is suitable for use in industrial automation systems. The transducer provides average root-mean-square (RMS) measurement for sinusoidal alternating voltage waveforms, with an accuracy of 0.5% full scale (FS) and a response time of 100 mS or shorter. Mounting options include DIN rail or panel. It is suitable for monitoring linear, constant-speed loads that produce sinusoidal waveforms. Warranty & Return 1.24 MONTHS QUALITY guarantee. Warranty : In the process of Exchanging products Buyer shoud bear freight of return shipping, while Manufactuer should bear freight of sending. 2.Buyer can return products and get FULL REFUND of item value within 30 days after receiving , if there\'s any quality problem in original products; Freight of return should be beard by manufacturer.
Input:0-500V ACPower Consumption: less than 0.3 VAWorking Stability: annual change < 0.2%Impulse Voltage:5KV(peak value),1.2/50uSLoad Capacity: 2 times current continuousStorage Environment:-40 to +115 degress Centigrade,20%-95% without condensationIsolation Withstanding Voltage:AC 2.0KV/min*1mA between input/output/powerOutput:0-5V DCPower Supply(defaulted):24V DC +/-15% (If 15V or 12V needed,please leave a message)Dimension:99*24*65mm(L*W*H)Accuracy:0.5% F.SFeature:Voltage Terminal Insert,standard din rail(35mm)mounting or pannel mountingWorking Environment:-25 to 80 degrees Centigrade,20%-90% without condensationIsolation Resistance:20M Ohm(DC500V) or aboveCapacity Max:0-500V AC (Customerized,contact operator if you need other input ranges,e.g.0-75mV or 0-300V)
상품설명
This voltage transducer combines a potential transformer and signal conditioner, and is suitable for use in industrial automation systems. The transducer provides average root-mean-square (RMS) measurement for sinusoidal alternating voltage waveforms, with an accuracy of 0.5% full scale (FS) and a response time of 100 mS or shorter. Mounting options include DIN rail or panel. It is suitable for monitoring linear, constant-speed loads that produce sinusoidal waveforms. Warranty & Return 1.24 MONTHS QUALITY guarantee. Warranty : In the process of Exchanging products Buyer shoud bear freight of return shipping, while Manufactuer should bear freight of sending. 2.Buyer can return products and get FULL REFUND of item value within 30 days after receiving , if there\'s any quality problem in original products; Freight of return should be beard by manufacturer.
2019-03-20 13:56:28