AMTAST Portable Turbidimeter Turbidity Meter Kit Turbidity Tester with 2 PCS Glass Sample Vials Range:0~1100 NTU/FNU, 0~275 EBC, 0~9999 ASBC
|
상품가격 상세보기
이벤트보기
|
- 상품상세정보
상품특징
Make sure this fits by entering your model number.Easy to operate, accurate results. Memory Stores up to 100 data setsUSB interface provided for data to be stored and transferred to your computerTwo measurement modes:the single measurment mode and the continuous measurementsWhen battery is depleted, you can use the USB cable connected to computer as a temporarily power supplyPackage List: AMT27 Turbidimeter; Glass Sample Vials (2 PCS) ; Default Calibration Standards: 0.02 NTU, 200 NTU, 500 NTU, 1000 NTU; Lint-free cloth; Carrying Case
상품설명
Size:One Size | Style:style1 Measurement Range: 0~1100 NTU/FNU, 0~275EBC, 0~9999 ASBC Resolution: 0.01(0~100 NTU), 0.1 (100~999NTU), 1 (999~1100 NTU) Accuracy: ±2%(0~500 NTU), ±3% (501~1100NTU) Default Calibration Standards: 0.02 NTU,200 NTU, 500 NTU, 1000 NTU or User-Defined Light Source: Infrared-emitting diode (850nm wave length) Detector: Silicon Photodiode Stray Light: <0.02 NTU Sample Vials: 60(H)×25(Dia)mm Power Off: Manualor Automatic (15 minutes) Reset Function: Yes Memory: Stores up to 100 data sets Output: USB Communication Interface Operating Temperature: 0~60°C Important Notes for Measurement and Calibration: Do not hold the meter in the hand during measurement and calibration. Glass vials and caps must be cleaned thoroughly with deionised water after each measurement. Minor residuals can cause errors. The outside of the vial must be clean and dry, before starting the test. Wipe the vial with alint-free cloth to remove fingerprints or water drops. If the vial has minor scratches or scuffs, add a few drops of silicone oil to outside of the vial. Wipe with lint-free cloth. For the low turbidity samples (0 to200NTU), we recommend that you use the same be aligned with the arrow on the meter. To avoid errors from ambient light interference, do not use the meter in bright sunlight. Always close the light shield lid during measurement and Calibration. Avoid spillage of water in the sample chamber. It may cause damage to the meter.
Make sure this fits by entering your model number.Easy to operate, accurate results. Memory Stores up to 100 data setsUSB interface provided for data to be stored and transferred to your computerTwo measurement modes:the single measurment mode and the continuous measurementsWhen battery is depleted, you can use the USB cable connected to computer as a temporarily power supplyPackage List: AMT27 Turbidimeter; Glass Sample Vials (2 PCS) ; Default Calibration Standards: 0.02 NTU, 200 NTU, 500 NTU, 1000 NTU; Lint-free cloth; Carrying Case
상품설명
Size:One Size | Style:style1 Measurement Range: 0~1100 NTU/FNU, 0~275EBC, 0~9999 ASBC Resolution: 0.01(0~100 NTU), 0.1 (100~999NTU), 1 (999~1100 NTU) Accuracy: ±2%(0~500 NTU), ±3% (501~1100NTU) Default Calibration Standards: 0.02 NTU,200 NTU, 500 NTU, 1000 NTU or User-Defined Light Source: Infrared-emitting diode (850nm wave length) Detector: Silicon Photodiode Stray Light: <0.02 NTU Sample Vials: 60(H)×25(Dia)mm Power Off: Manualor Automatic (15 minutes) Reset Function: Yes Memory: Stores up to 100 data sets Output: USB Communication Interface Operating Temperature: 0~60°C Important Notes for Measurement and Calibration: Do not hold the meter in the hand during measurement and calibration. Glass vials and caps must be cleaned thoroughly with deionised water after each measurement. Minor residuals can cause errors. The outside of the vial must be clean and dry, before starting the test. Wipe the vial with alint-free cloth to remove fingerprints or water drops. If the vial has minor scratches or scuffs, add a few drops of silicone oil to outside of the vial. Wipe with lint-free cloth. For the low turbidity samples (0 to200NTU), we recommend that you use the same be aligned with the arrow on the meter. To avoid errors from ambient light interference, do not use the meter in bright sunlight. Always close the light shield lid during measurement and Calibration. Avoid spillage of water in the sample chamber. It may cause damage to the meter.
2019-03-20 23:34:31