Protactor 1 Pole 32 AMP Heavy Duty AC Contactor Replaces Virtually All Residential 1 Pole Models 30 Amps or Less
|
상품가격 상세보기
이벤트보기
|
- 상품상세정보
상품특징
Make sure this fits by entering your model number.Protactor 2 Year Replacement Policy32 FLA Amp Rating - 1 Pole With Shunt - 24 Volt Coil. Replaces Most 1 Pole Contactors Rated at 20 Amps, 25 Amps, or 30 Amps on Air Conditioners and Heat PumpsEnclosed Contacts and Encapsulated 24 Volt CoilHeavy Lug Terminals and Push-Ons for High Voltage ConnectionsReplaces Virtually All 1 Pole Contactors 32 Amps or Less Used by Carrier - Bryant - Payne, Rheem - Ruud - Weatherking, Lennox - Armstrong - Ducane, Trane - American Standard, York - Coleman - Evcon - Luxaire, Heil - Comfortmaker - Tempstar
상품설명
This contactor is a heavy duty enclosed replacement for all one pole contactors rated at 32 Amps or less which have 24 volt coils. This contactor is rated at 32 Amps and has a 24 Volt coil. This contactor has a heavy lug terminal and 4 male quick connect ¼” terminals on each line voltage connection to provide maximum wiring flexibility. The two terminals for the low voltage coil each have double ¼” male quick connects. The contact mechanism is enclosed to keep out insects and debris, but the visible plunger provides positive verification that the contacts are pulled in. The coil is encapsulated with no exposed tape wrapping. The mounting base measures 2-5/16” X 1-15/16” with four oblong mounting holes 1-5/8” x 1-5/8” on center. There are also four slots in the base to provide many mounting options. This part replaces most residential one pole contactors 32 Amps or less. This part is covered by the exclusive Protactor two year limited replacement policy. If this part fails within two years from date of purchase, return the defective part and a copy of the original invoice to the place of purchase for replacement. Contact the authorized Protactor dealer that you purchased the part from for details. Original equipment manufacturer's brand name(s) and part numbers are used for identification purposes only. This item is supplied by Protactor and meets or exceeds original equipment specifications.
Make sure this fits by entering your model number.Protactor 2 Year Replacement Policy32 FLA Amp Rating - 1 Pole With Shunt - 24 Volt Coil. Replaces Most 1 Pole Contactors Rated at 20 Amps, 25 Amps, or 30 Amps on Air Conditioners and Heat PumpsEnclosed Contacts and Encapsulated 24 Volt CoilHeavy Lug Terminals and Push-Ons for High Voltage ConnectionsReplaces Virtually All 1 Pole Contactors 32 Amps or Less Used by Carrier - Bryant - Payne, Rheem - Ruud - Weatherking, Lennox - Armstrong - Ducane, Trane - American Standard, York - Coleman - Evcon - Luxaire, Heil - Comfortmaker - Tempstar
상품설명
This contactor is a heavy duty enclosed replacement for all one pole contactors rated at 32 Amps or less which have 24 volt coils. This contactor is rated at 32 Amps and has a 24 Volt coil. This contactor has a heavy lug terminal and 4 male quick connect ¼” terminals on each line voltage connection to provide maximum wiring flexibility. The two terminals for the low voltage coil each have double ¼” male quick connects. The contact mechanism is enclosed to keep out insects and debris, but the visible plunger provides positive verification that the contacts are pulled in. The coil is encapsulated with no exposed tape wrapping. The mounting base measures 2-5/16” X 1-15/16” with four oblong mounting holes 1-5/8” x 1-5/8” on center. There are also four slots in the base to provide many mounting options. This part replaces most residential one pole contactors 32 Amps or less. This part is covered by the exclusive Protactor two year limited replacement policy. If this part fails within two years from date of purchase, return the defective part and a copy of the original invoice to the place of purchase for replacement. Contact the authorized Protactor dealer that you purchased the part from for details. Original equipment manufacturer's brand name(s) and part numbers are used for identification purposes only. This item is supplied by Protactor and meets or exceeds original equipment specifications.
2019-05-19 11:52:01