DA-102 can be operated by DC 9V Alkaline Batteery (6LR61T), DC9V Adapter and the Output port for power supply. To maximize longevity, the unit runs ten minutes every hour (power save mode) when the battery is used. You may use DC 9V adapter, then it is automatically changed to a continuous usage (normal mode). DA-102 displays wide ranged information and secure signals such as temperature, normal, refill and alarm mute, Icon bars indicate liquid nitrogen and battery levels. The unit holder (clip) can be easity attached and removed to/from any side of nitrogen tank using faces tape. Using a cable of three wises, the Output allows the Phone Master, Alarm Master and DC 9V adapter for power supply. 1) Size : 61 x 92 x 23 mm 2) electronic English manual ( not paper ) 3) Specifications ( includes ) Weight : 70 g LCD Size10 x 11 x 111 mm Sensor : Platinum Resistance Thermometer Sensor Connector : One Touch Connector Temperature Range : -80℃ ~ -199℃ Program Range : -80℃ ~ -196℃ Output : Open Out Method (4~20 mA), Combined Power Automatic Power Supply : Continuous mode when using adapter Change Mode : Economic mode when using battery Standby Current : Max 10 mA (Economic mode: 3mA) LN2 Status Display : 7 bars on LCD Battery Status Display : 4 bars on LCD Unit Holder : Complete with mounting taped holder Adapter : DC 9V 300mA Battery : DC 9V Alkaline (6LR61T) ( NOT includes, you can find this battery in your side )
DA-102 can be operated by DC 9V Alkaline Batteery (6LR61T), DC9V Adapter and the Output port for power supply. To maximize longevity, the unit runs ten minutes every hour (power save mode) when the battery is used. You may use DC 9V adapter, then it is automatically changed to a continuous usage (normal mode). DA-102 displays wide ranged information and secure signals such as temperature, normal, refill and alarm mute, Icon bars indicate liquid nitrogen and battery levels. The unit holder (clip) can be easity attached and removed to/from any side of nitrogen tank using faces tape. Using a cable of three wises, the Output allows the Phone Master, Alarm Master and DC 9V adapter for power supply. 1) Size : 61 x 92 x 23 mm 2) electronic English manual ( not paper ) 3) Specifications ( includes ) Weight : 70 g LCD Size10 x 11 x 111 mm Sensor : Platinum Resistance Thermometer Sensor Connector : One Touch Connector Temperature Range : -80℃ ~ -199℃ Program Range : -80℃ ~ -196℃ Output : Open Out Method (4~20 mA), Combined Power Automatic Power Supply : Continuous mode when using adapter Change Mode : Economic mode when using battery Standby Current : Max 10 mA (Economic mode: 3mA) LN2 Status Display : 7 bars on LCD Battery Status Display : 4 bars on LCD Unit Holder : Complete with mounting taped holder Adapter : DC 9V 300mA Battery : DC 9V Alkaline (6LR61T) ( NOT includes, you can find this battery in your side )
2019-03-20 10:59:00