Programmable 400W DC Electronic Load Battery Load Tester DC Tester 0-150V 0-40A (USB)
|
상품가격 상세보기
이벤트보기
|
- 상품상세정보
상품특징
Make sure this fits by entering your model number.Note: there is a knob on the back of the load meter to select the 110V or 220V input voltage, please check if the knob is in the proper position before powering on; the factory setting defaults to small range (3A 21V 36W), you can convert it to 0-150V 0-40A 400W by setting; when it is turned on, click Shift, then press Esc, enter SYS Menu, select Option1 (Load set), click Enter, set the power, current, voltage through the knob, after setting, click ESC to exit and saveProvides several measurement modes of CC CV CR CP and CC+CV CR+CVDynamic test mode to test power supply dynamic output performance; scan test mode to test power output continuity within a certain rangeIntelligent fan speed control function to effectively reduce fan noise during operationOver-voltage, over-current, over-power protection, flexible setting of over-voltage and over-current parameters for effective protection of the load
상품설명
Size:USB Features: 2.8-inch TFT LCD screen, easy to operate Key lock function to prevent misoperation Provide battery and LED testing List mode to simulate multiple load state changes Short circuit test for analog load short circuit Support for external trigger input Built-in buzzer alarm Power off to maintain data storage PS2 interface, support external keyboard to set data values Output polarity reverse protection, secondary over temperature protection Parameters: Channel: single channel Rated input: Power: 400W Input voltage: 0-150V Input current: 0-40A Constant power mode: Range: 0.1-19.999V; 0.1-150.00V Resolution: 1mV; 10mV Accuracy: ± (0.05% + 0.02% FS) Constant current mode: Range: 0-3.000A; 0-40.00A Resolution: 1mA; 10mA Accuracy: ± (0.05% + 0.05% FS) Constant resistance mode: Range: 0.05-10Ω; 10Ω-7.5kΩ Resolution: 16bit Accuracy: ± (0.1% + 0.8% FS) Constant power mode: Range: 0-400W Resolution: 10mW Accuracy: ± (0.1% + 0.1% FS) Dynamic test function: Mode: CC T1&T2: 50μS-3600S; resolution: 1μs Accuracy: 0.1%+5μs Rise/fall slope: 0.000-0.3A/μs (current 0-3.000A); 0.000-1.5A/μs (current 3.000-40.00A) Battery test function: Voltage range: 0-120V Discharge capacity: 240Ah Resolution: 1mA Test time: 1s-16h Voltage readback value: Range: 0-9.999V; 0-150.00V Resolution: 1mV/10mV Accuracy: ± (0.05% + 0.1% FS) Current readback value: Range: 0-3.000A; 0-40.00A Resolution: 1mA/10mA Accuracy: ± (0.05% + 0.1% FS) Power readback value: Range: 400W Resolution: 10mW Accuracy: ± (0.1% + 0.1% FS) Overvoltage protection: >150V cut-off input Overcurrent protection: >40A cut-off input Over power protection: 400W Over temperature protection: 85°C
Make sure this fits by entering your model number.Note: there is a knob on the back of the load meter to select the 110V or 220V input voltage, please check if the knob is in the proper position before powering on; the factory setting defaults to small range (3A 21V 36W), you can convert it to 0-150V 0-40A 400W by setting; when it is turned on, click Shift, then press Esc, enter SYS Menu, select Option1 (Load set), click Enter, set the power, current, voltage through the knob, after setting, click ESC to exit and saveProvides several measurement modes of CC CV CR CP and CC+CV CR+CVDynamic test mode to test power supply dynamic output performance; scan test mode to test power output continuity within a certain rangeIntelligent fan speed control function to effectively reduce fan noise during operationOver-voltage, over-current, over-power protection, flexible setting of over-voltage and over-current parameters for effective protection of the load
상품설명
Size:USB Features: 2.8-inch TFT LCD screen, easy to operate Key lock function to prevent misoperation Provide battery and LED testing List mode to simulate multiple load state changes Short circuit test for analog load short circuit Support for external trigger input Built-in buzzer alarm Power off to maintain data storage PS2 interface, support external keyboard to set data values Output polarity reverse protection, secondary over temperature protection Parameters: Channel: single channel Rated input: Power: 400W Input voltage: 0-150V Input current: 0-40A Constant power mode: Range: 0.1-19.999V; 0.1-150.00V Resolution: 1mV; 10mV Accuracy: ± (0.05% + 0.02% FS) Constant current mode: Range: 0-3.000A; 0-40.00A Resolution: 1mA; 10mA Accuracy: ± (0.05% + 0.05% FS) Constant resistance mode: Range: 0.05-10Ω; 10Ω-7.5kΩ Resolution: 16bit Accuracy: ± (0.1% + 0.8% FS) Constant power mode: Range: 0-400W Resolution: 10mW Accuracy: ± (0.1% + 0.1% FS) Dynamic test function: Mode: CC T1&T2: 50μS-3600S; resolution: 1μs Accuracy: 0.1%+5μs Rise/fall slope: 0.000-0.3A/μs (current 0-3.000A); 0.000-1.5A/μs (current 3.000-40.00A) Battery test function: Voltage range: 0-120V Discharge capacity: 240Ah Resolution: 1mA Test time: 1s-16h Voltage readback value: Range: 0-9.999V; 0-150.00V Resolution: 1mV/10mV Accuracy: ± (0.05% + 0.1% FS) Current readback value: Range: 0-3.000A; 0-40.00A Resolution: 1mA/10mA Accuracy: ± (0.05% + 0.1% FS) Power readback value: Range: 400W Resolution: 10mW Accuracy: ± (0.1% + 0.1% FS) Overvoltage protection: >150V cut-off input Overcurrent protection: >40A cut-off input Over power protection: 400W Over temperature protection: 85°C
2020-08-05 13:09:21