Specification: Rated Voltage: AC 220V/ 50~60Hz/ 4A, or AC 110V/ 50~60Hz/ 8A if request. Rated Power: 1600VA Fuse: T10A AC220V /T25A AC110V Operation Temperature: 5~40℃ Noise :< 50db The Max. capacity of a plate:1000g Sterilizer Chamber Material: stainless steel 304 (for medical) Work Pressure: -0.9 bar~2.5 bar Max. Temperature: 145 ℃ Chamber Volume: 18L(Φ245×350mm) Loading Size: 18L (537×417×410) Working Pressure/Temperature: 1.1~1.3bar/ 121~122℃; 2.1~2.3bar/ 134~135℃ Water Volume for One Cycle: 0.16L~0.18L Sterilizer Steam Safety Valve Safety Release Pressure: 2.45 bar Max. Working Temperature: 160 ℃ N./G. Weight 25/28 KGs Packing Size 600x460x455mm Function 1.Connect one end of the draining tube to the equipment and put the other end into the waste water tank. 2.Load the trays into the chamber with tray removal tool, and put the instruments which need to be sterilized on the trays. 3.Close the door. 4.Turn on the power switch, then set the sterilization temperature, temperature select switch ON: 134℃/ 0.22Mpa/ 5mins, temperature selection OFF:121℃/ 0.12Mpa/ 20mins. It will start sterilization cycle automatically. 5.When the cycle is finished, the screen will show ED. CAUTION:PLEASE DO NOT OPEN THE DOOR UNTIL THE PRESSURE INSIDE CHAMBER FALLS TO 0 BAR. 6. Please turn off the power switch and take the instruments out. Package with: 1. Mini 320 steam sterilizer 1 piece 2. Tray rack 1 piece 3. Tray 3 pcs 4. Removal tool 1 piece 5. Draining tube 1 piece 6. Power supply cable 1 piece
Specification: Rated Voltage: AC 220V/ 50~60Hz/ 4A, or AC 110V/ 50~60Hz/ 8A if request. Rated Power: 1600VA Fuse: T10A AC220V /T25A AC110V Operation Temperature: 5~40℃ Noise :< 50db The Max. capacity of a plate:1000g Sterilizer Chamber Material: stainless steel 304 (for medical) Work Pressure: -0.9 bar~2.5 bar Max. Temperature: 145 ℃ Chamber Volume: 18L(Φ245×350mm) Loading Size: 18L (537×417×410) Working Pressure/Temperature: 1.1~1.3bar/ 121~122℃; 2.1~2.3bar/ 134~135℃ Water Volume for One Cycle: 0.16L~0.18L Sterilizer Steam Safety Valve Safety Release Pressure: 2.45 bar Max. Working Temperature: 160 ℃ N./G. Weight 25/28 KGs Packing Size 600x460x455mm Function 1.Connect one end of the draining tube to the equipment and put the other end into the waste water tank. 2.Load the trays into the chamber with tray removal tool, and put the instruments which need to be sterilized on the trays. 3.Close the door. 4.Turn on the power switch, then set the sterilization temperature, temperature select switch ON: 134℃/ 0.22Mpa/ 5mins, temperature selection OFF:121℃/ 0.12Mpa/ 20mins. It will start sterilization cycle automatically. 5.When the cycle is finished, the screen will show ED. CAUTION:PLEASE DO NOT OPEN THE DOOR UNTIL THE PRESSURE INSIDE CHAMBER FALLS TO 0 BAR. 6. Please turn off the power switch and take the instruments out. Package with: 1. Mini 320 steam sterilizer 1 piece 2. Tray rack 1 piece 3. Tray 3 pcs 4. Removal tool 1 piece 5. Draining tube 1 piece 6. Power supply cable 1 piece
2019-04-28 16:37:10