UTMD WIT601V Veterinary Infusion Pump with 5 Years Warranty High Accurate 12 Working Modes
|
상품가격 상세보기
이벤트보기
|
- 상품상세정보
상품특징
Including 12 kinds working mode: Volume / Drop / Micro / Programme / DOSE Weight / Drug Lab. / Manual Bolus.A new generation of accuracy calibration technology, could directly enter the calibration value to fast calibrate of the machine batch, greatly enhance the efficiency of installation and maintenance.Comfort design with heater, Improve the experience of patients in low temperature infusion.Support changes the Rate, Time, Dose, VTBI & other important parameters during the infuse working. 项目符号With the unique alarm: Pre-alarm of end infuse, Pre-alarm of high pressure block and etc. to meet the needs of special treatment. Powerful safety self-check function to ensure the pump working properly.
상품설명
Drug Lab.: Built-in 500 kinds of drugs, covering the clinical use of the drug dose of 54 units on the library, and could be connect with the PC for edit; export & import. Working Mode: Rate/VTBI,Time/VTBI,Rate/Time,Volume,Drop,Micro,Simple Rate,Programmable,DOSE Weight,Drug Lab,Auto Bolus,Manual Bolus. IV Set: Open System for 10d/ml,15d/ml,20d/ml,60d/ml (3.4mm - 4.5mm); IV Set management: could add / remove / edit more than 40 kinds tubes; Accuracy: Volume Mode:≤ ±5%,Drop Mode:≤ ±2% (after calibrate); Calibrate: Automatic or manual calibration of infusion accuracy; Rate: Volume: 0.1ml/h~1200ml/h, Purge: 600ml/h; Drop: 1d/min~400d/min, VTBI: 1~9999 ml or OFF; Total Volume Σ: 0~9999.9 ml; KVO: 1ml/h~5ml/h Adjustable,Default: 1ml/h; Programmable: Maximum 8 steps of different infuse rate / time / VTBI; BOLUS: Manual Bolus:long Press the Bolus key to infuse and release to stop; Auto Bolus: short press the Bolus key and set the VTBI & Rate. Upper Pressure: High / Middle / Low, 3 level, could off on the menu. Down Pressure: 200mmHg - 1200mmHg, 20 level, live pressure display, mmHg & kPa two units. Pre-Alarm Occlusion: When the pressure in the tube goes up, it has the function of early warning. Pre-Alarm Finish: 1 min~30 min, The alarm can be set ahead of VTBI. Parameters Modify: changes the Rate, Time, Dose, VTBI & other important parameters during the infuse working. Keypad Locker: Manual / Auto lock keyboard. History Record: Record 20000 infuse records, 10000 alarm records, can be downloaded to the computer. Self-Test: safety real time self-test function to ensure the pump working properly. Bubble: Detected by ultrasonic sensor with adjust setting 5 level, 50μL ~ 800μL. Drop Sensor: Infrared sensor to detect the number of drops, monitoring the status in case the empty bottles. Alarm: Bubble, Door open, Finish, Pause timeout, Down Occlusion, Up Occlusion, Lower Battery or damage, Motor error, Incorrect IV Set-type, Pressure test failure, Motor failure, etc
Including 12 kinds working mode: Volume / Drop / Micro / Programme / DOSE Weight / Drug Lab. / Manual Bolus.A new generation of accuracy calibration technology, could directly enter the calibration value to fast calibrate of the machine batch, greatly enhance the efficiency of installation and maintenance.Comfort design with heater, Improve the experience of patients in low temperature infusion.Support changes the Rate, Time, Dose, VTBI & other important parameters during the infuse working. 项目符号With the unique alarm: Pre-alarm of end infuse, Pre-alarm of high pressure block and etc. to meet the needs of special treatment. Powerful safety self-check function to ensure the pump working properly.
상품설명
Drug Lab.: Built-in 500 kinds of drugs, covering the clinical use of the drug dose of 54 units on the library, and could be connect with the PC for edit; export & import. Working Mode: Rate/VTBI,Time/VTBI,Rate/Time,Volume,Drop,Micro,Simple Rate,Programmable,DOSE Weight,Drug Lab,Auto Bolus,Manual Bolus. IV Set: Open System for 10d/ml,15d/ml,20d/ml,60d/ml (3.4mm - 4.5mm); IV Set management: could add / remove / edit more than 40 kinds tubes; Accuracy: Volume Mode:≤ ±5%,Drop Mode:≤ ±2% (after calibrate); Calibrate: Automatic or manual calibration of infusion accuracy; Rate: Volume: 0.1ml/h~1200ml/h, Purge: 600ml/h; Drop: 1d/min~400d/min, VTBI: 1~9999 ml or OFF; Total Volume Σ: 0~9999.9 ml; KVO: 1ml/h~5ml/h Adjustable,Default: 1ml/h; Programmable: Maximum 8 steps of different infuse rate / time / VTBI; BOLUS: Manual Bolus:long Press the Bolus key to infuse and release to stop; Auto Bolus: short press the Bolus key and set the VTBI & Rate. Upper Pressure: High / Middle / Low, 3 level, could off on the menu. Down Pressure: 200mmHg - 1200mmHg, 20 level, live pressure display, mmHg & kPa two units. Pre-Alarm Occlusion: When the pressure in the tube goes up, it has the function of early warning. Pre-Alarm Finish: 1 min~30 min, The alarm can be set ahead of VTBI. Parameters Modify: changes the Rate, Time, Dose, VTBI & other important parameters during the infuse working. Keypad Locker: Manual / Auto lock keyboard. History Record: Record 20000 infuse records, 10000 alarm records, can be downloaded to the computer. Self-Test: safety real time self-test function to ensure the pump working properly. Bubble: Detected by ultrasonic sensor with adjust setting 5 level, 50μL ~ 800μL. Drop Sensor: Infrared sensor to detect the number of drops, monitoring the status in case the empty bottles. Alarm: Bubble, Door open, Finish, Pause timeout, Down Occlusion, Up Occlusion, Lower Battery or damage, Motor error, Incorrect IV Set-type, Pressure test failure, Motor failure, etc
2021-01-16 22:12:41