Dwyer Averaging Air Flow Grid, 160G, Extends Over 50" to Aid in Air Flow Output Checks
|
상품가격 상세보기
이벤트보기
|
- 상품상세정보
상품특징
Make sure this fits by entering your model number.Accuracy: ±2% FS.Temperature Limits: -40 to 257°F (-40° to 125°C).Range: 1000 to 5000 FPM (5 to 25 m/s).Process Connection: 1/8 to 1/4" ID tubing.
상품설명
The Dwyer Model 160G Averaging Air Flow Grid is a precision sensing instrument used to measure face air velocity on grills, diffusers, registers, exhaust hoods, coils, filters, dampers and similar restrictions. With its 16 sensing points, the 160G Air Flow Grid provides an average flow sensing area across its 16.5" length and width. Included color coded tubing connects to the integral barbed fittings, providing a Differential Pressure signal to a gage or manometer where the readings can be converted into a velocity or flow reading. The 160G comes standard with an 18" handle and two 17" extensions offering a maximum reach of approximately 52". The uniquely designed swivel and tightening nut allows the user to position the sensing grid at any angle for ease of use in hard to reach locations. Store in the separate UHH-C2 hard carrying case with foam cut-outs perfectly sized for the 160G, as well as various other instruments in the AQTI Air Quality Test Instruments line.
Make sure this fits by entering your model number.Accuracy: ±2% FS.Temperature Limits: -40 to 257°F (-40° to 125°C).Range: 1000 to 5000 FPM (5 to 25 m/s).Process Connection: 1/8 to 1/4" ID tubing.
상품설명
The Dwyer Model 160G Averaging Air Flow Grid is a precision sensing instrument used to measure face air velocity on grills, diffusers, registers, exhaust hoods, coils, filters, dampers and similar restrictions. With its 16 sensing points, the 160G Air Flow Grid provides an average flow sensing area across its 16.5" length and width. Included color coded tubing connects to the integral barbed fittings, providing a Differential Pressure signal to a gage or manometer where the readings can be converted into a velocity or flow reading. The 160G comes standard with an 18" handle and two 17" extensions offering a maximum reach of approximately 52". The uniquely designed swivel and tightening nut allows the user to position the sensing grid at any angle for ease of use in hard to reach locations. Store in the separate UHH-C2 hard carrying case with foam cut-outs perfectly sized for the 160G, as well as various other instruments in the AQTI Air Quality Test Instruments line.
2020-03-14 06:12:47