18 AWG TFFN, 16 Stranded Copper Fixture Wire in 500Ft Reel (White)
|
상품가격 상세보기
이벤트보기
|
- 상품상세정보
상품특징
APPLICATIONS: Use as fixture wire, machine tool wiring, or appliance wiringCONSTRUCTION: Copper conductors are annealed (soft) copper, insulated with a tough heat and moisture resistant Polyvinyl Chloride (PVC)STANDARDS: UL Listed and RoHS CompliantSPECIFICATIONS: For use in wet locations or when exposed to oil or coolant at temperatures not to exceed 60 degrees Celsius or dry locations at temperatures not to exceed 90 Degrees CelciusALLOWABLE AMPACITY: TFFN allows 6 Amps. Voltage for all applications is 600 Volts
상품설명
Applications: Type TFFN or MTW or AWM may be used as fixture wire, machine tool wiring, or appliance wiring material as specified in the 2008 National Electrical Code. When used as Type TFFN, conductor is suitable for use at temperatures not to exceed 90°C. When used as Type MTW, conductor is suitable for use in wet locations or when exposed to oil or coolant at temperatures not to exceed 60°C or dry locations at temperatures not to exceed 90°C (with ampacity limited to that for 75°C conductor temperature per NFPA 79). Conductor temperatures not to exceed 105°C in dry locations when rated AWM and used as appliance wiring material. Voltage for all applications is 600 volts. Standards: UL Standard 66 National Electrical Code RoHS Compliant Construction: Type TFFN or MTW or AWM copper conductors are annealed (soft) copper, insulated with a tough, heat and moisture resistant polyvinyl chloride (PVC), over which a nylon (polyamide) jacket is applied. Specifications: Size: 18 AWG Number of Strands: 16 Vinyl Insulation Thickness: 0.015 Inches Nylon Jacket Thickness: 0.004 Inches Outside Diameter: 0.085 Inches Weight: 0.012 lbs/ft Allowable Ampacity: TFFN - 6 Amps / MTW - 7 Amps
APPLICATIONS: Use as fixture wire, machine tool wiring, or appliance wiringCONSTRUCTION: Copper conductors are annealed (soft) copper, insulated with a tough heat and moisture resistant Polyvinyl Chloride (PVC)STANDARDS: UL Listed and RoHS CompliantSPECIFICATIONS: For use in wet locations or when exposed to oil or coolant at temperatures not to exceed 60 degrees Celsius or dry locations at temperatures not to exceed 90 Degrees CelciusALLOWABLE AMPACITY: TFFN allows 6 Amps. Voltage for all applications is 600 Volts
상품설명
Applications: Type TFFN or MTW or AWM may be used as fixture wire, machine tool wiring, or appliance wiring material as specified in the 2008 National Electrical Code. When used as Type TFFN, conductor is suitable for use at temperatures not to exceed 90°C. When used as Type MTW, conductor is suitable for use in wet locations or when exposed to oil or coolant at temperatures not to exceed 60°C or dry locations at temperatures not to exceed 90°C (with ampacity limited to that for 75°C conductor temperature per NFPA 79). Conductor temperatures not to exceed 105°C in dry locations when rated AWM and used as appliance wiring material. Voltage for all applications is 600 volts. Standards: UL Standard 66 National Electrical Code RoHS Compliant Construction: Type TFFN or MTW or AWM copper conductors are annealed (soft) copper, insulated with a tough, heat and moisture resistant polyvinyl chloride (PVC), over which a nylon (polyamide) jacket is applied. Specifications: Size: 18 AWG Number of Strands: 16 Vinyl Insulation Thickness: 0.015 Inches Nylon Jacket Thickness: 0.004 Inches Outside Diameter: 0.085 Inches Weight: 0.012 lbs/ft Allowable Ampacity: TFFN - 6 Amps / MTW - 7 Amps


2025-01-06 23:11:54